!01_04-f8-f8-79-fb-db_03 ! ! ! !--- !--- ! clock timezone EET hours 2 minute 0 ! ntp client ntp server 100.127.255.254 ! prompt st-sw-x-kpp hostname st-sw-x-kpp snmp-server location "X, KPP" snmp-server contact hostmaster@gal.net.ua ! jumbo frame ! ! ! clock summer-time EET predefined europe ! ! network-access aging ! ! ! ! snmp-server community snmpkpp ro ! ! ! username admin access-level 15 username admin password 7 166b458e6e6b84e2608cc332e682de84 no username guest username user access-level 15 username user password 7 726dedc0d6788b05f486730edcc0e871 enable password 7 1b3231655cebb7a1f783eddf27d254ca ! ! logging facility 20 logging host 100.127.255.253 port 514 logging host 100.127.255.254 port 514 logging trap ! ! ! ! vlan database VLAN 1 name DefaultVlan media ethernet VLAN 36 name 36-telephony media ethernet VLAN 37 name 37-guset media ethernet VLAN 38 name 38-interconnetc media ethernet VLAN 40 name 40-mgnt.kpp media ethernet VLAN 41 name 41-ISP_CORE media ethernet VLAN 42 name 42-ISP2 media ethernet VLAN 43 name 43-office.main media ethernet VLAN 44 name 44-terminal media ethernet VLAN 45 name 45-interconnect media ethernet VLAN 47 name 47-FTP media ethernet VLAN 51 name 51-ISP.KS media ethernet VLAN 52 name 52-trnsp_swx-sw4 media ethernet VLAN 80 name 80-ISP media ethernet VLAN 81 name 81-LAN media ethernet VLAN 82 name 82-guest media ethernet VLAN 83 name 83-starlink media ethernet VLAN 84 name 84-lan media ethernet VLAN 2005 name 2005-l2l media ethernet VLAN 4094 name 4094-stub media ethernet vlan 16,46,48-49,54-58 media ethernet ! ! ! ! ! ! spanning-tree ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! loopback-detection action block ! interface ethernet 1/1 spanning-tree loopback-detection description serv no lldp notification no lldp admin-status switchport allowed vlan add 43 untagged switchport mode access switchport native vlan 43 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/2 spanning-tree loopback-detection description serv no lldp notification no lldp admin-status switchport allowed vlan add 43 untagged switchport mode access switchport native vlan 43 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/3 spanning-tree loopback-detection description MT_backup_ether1 switchport mode trunk switchport native vlan 81 switchport acceptable-frame-types tagged switchport allowed vlan add 40-41,43-45,47,81-82,84,2005,4094 tagged switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/4 spanning-tree loopback-detection description serv no lldp notification no lldp admin-status switchport allowed vlan add 43 untagged switchport mode access switchport native vlan 43 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/5 spanning-tree loopback-detection description vid80-ISP no lldp notification no lldp admin-status switchport allowed vlan add 81 untagged switchport native vlan 81 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/6 spanning-tree loopback-detection description _FREE no lldp notification no lldp admin-status switchport allowed vlan add 43 untagged switchport mode access switchport native vlan 43 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/7 spanning-tree loopback-detection description serv no lldp notification no lldp admin-status switchport allowed vlan add 43 untagged switchport native vlan 43 switchport allowed vlan add 41,47,81 tagged switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/8 spanning-tree loopback-detection description serv no lldp notification no lldp admin-status switchport allowed vlan add 43 untagged switchport native vlan 43 switchport allowed vlan add 37,81 tagged switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/9 spanning-tree loopback-detection description MT_backup_ether2 switchport mode trunk switchport native vlan 80 switchport acceptable-frame-types tagged switchport allowed vlan add 38,80,83 tagged switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/10 spanning-tree loopback-detection description serv no lldp notification no lldp admin-status switchport allowed vlan add 43 untagged switchport native vlan 43 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/11 spanning-tree loopback-detection description serv no lldp notification no lldp admin-status switchport allowed vlan add 81 untagged switchport mode access switchport native vlan 81 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/12 spanning-tree loopback-detection description serv no lldp notification no lldp admin-status switchport allowed vlan add 43 untagged switchport native vlan 43 switchport allowed vlan add 81 tagged switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/13 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 43 untagged switchport mode access switchport native vlan 43 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/14 spanning-tree loopback-detection description serv no lldp notification no lldp admin-status switchport allowed vlan add 81 untagged switchport native vlan 81 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/15 spanning-tree loopback-detection description vid81 no lldp notification no lldp admin-status switchport allowed vlan add 81 untagged switchport mode access switchport native vlan 81 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/16 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 43 untagged switchport mode access switchport native vlan 43 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/17 spanning-tree loopback-detection description _FREE no lldp notification no lldp admin-status switchport allowed vlan add 80 untagged switchport mode access switchport native vlan 80 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/18 spanning-tree loopback-detection description _FREE no lldp notification no lldp admin-status switchport allowed vlan add 81 untagged switchport native vlan 81 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/19 spanning-tree loopback-detection description serv no lldp notification no lldp admin-status switchport allowed vlan add 43 untagged switchport native vlan 43 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/20 spanning-tree loopback-detection description serv no lldp notification no lldp admin-status switchport allowed vlan add 43 untagged switchport native vlan 43 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/21 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport mode trunk switchport native vlan 43 switchport acceptable-frame-types tagged switchport allowed vlan add 2005 tagged switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/22 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 43 untagged switchport mode access switchport native vlan 43 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/23 spanning-tree loopback-detection description serv no lldp notification no lldp admin-status switchport allowed vlan add 43 untagged switchport native vlan 43 switchport allowed vlan add 41,47,81 tagged switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/24 spanning-tree loopback-detection description serv no lldp notification no lldp admin-status switchport allowed vlan add 43 untagged switchport native vlan 43 switchport allowed vlan add 2005 tagged switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/25 description trnsp-sw0.p24 switchport broadcast packet-rate 500 switchport multicast packet-rate 500 switchport unknown-unicast packet-rate 500 switchport mode trunk switchport native vlan 40 switchport acceptable-frame-types tagged switchport allowed vlan add 36,40-41,43-49,51-52,54-58,81,84,2005,4094 tagged switchport allowed vlan remove 1 ! interface ethernet 1/26 description trnsp-sw0.p2 switchport broadcast packet-rate 500 switchport multicast packet-rate 500 switchport unknown-unicast packet-rate 500 switchport mode trunk switchport native vlan 40 switchport acceptable-frame-types tagged switchport allowed vlan add 36,40-41,43-49,51-52,54-58,81,2005,4094 tagged switchport allowed vlan remove 1 ! interface ethernet 1/27 description sw2-x-kpp switchport mode trunk switchport native vlan 40 switchport acceptable-frame-types tagged switchport allowed vlan add 36-38,40-41,43-49,51,54-58,80-84,2005,4094 tagged switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/28 spanning-tree loopback-detection description ISP no lldp notification no lldp admin-status switchport allowed vlan add 80 untagged switchport mode access switchport native vlan 80 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! ! ! ! ! interface vlan 38 ip address 192.168.13.3 255.255.255.0 ! interface vlan 40 ip address 192.168.12.11 255.255.255.0 ! interface vlan 4094 ip address 192.168.83.4 255.255.255.248 ! ! ! ! ! ! management http-client 10.20.1.1 10.20.1.1 management http-client 100.127.255.254 100.127.255.254 management http-client 192.168.10.1 192.168.10.254 management http-client 192.168.12.1 192.168.12.254 management http-client 192.168.13.1 192.168.13.1 management snmp-client 10.20.1.1 10.20.1.254 management snmp-client 100.127.255.254 100.127.255.254 management snmp-client 192.168.12.1 192.168.12.254 management snmp-client 192.168.13.1 192.168.13.1 management telnet-client 100.127.255.254 100.127.255.254 management telnet-client 192.168.12.1 192.168.12.254 management telnet-client 192.168.13.1 192.168.13.1 ! ! ! ip name-server 192.168.10.1 ip domain-lookup ! ! ! ! ! ! ! ! ! ip route 0.0.0.0 0.0.0.0 192.168.12.1 ! ! ! ! spanning-tree pathcost method short spanning-tree priority 4096 ! ! ! ! ! ! radius-server 1 host 10.20.1.250 auth-port 1812 acct-port 1813 timeout 5 retransmit 2 encrypted-key a3Bwa2V5 ! authentication login local radius ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! interface vlan 38 ! interface vlan 40 ! interface vlan 4094 ipv6 nd dad attempts 0 ! ! ! ! ! ! ! ! ! ! ! line console ! ! line vty ! ! ! end ! ! System Description : ECS4100-28T ! System OID String : 1.3.6.1.4.1.259.10.1.46.104 ! System Information ! System Name : st-sw-x-kpp ! System Location : X, KPP ! System Contact : hostmaster@gal.net.ua ! MAC Address (Unit 1) : 04-F8-F8-79-FB-DB ! Web Server : Enabled ! Web Server Port : 80 ! Web Secure Server : Enabled ! Web Secure Server Port : 443 ! Telnet Server : Enabled ! Telnet Server Port : 23 ! Authentication Login : Local RADIUS None ! Jumbo Frame : Enabled ! Unit 1 ! ! Main Power Status : Up ! Unit 1 ! Serial Number : EC2016005833 ! Hardware Version : R02A ! Number of Ports : 28 ! Main Power Status : Up ! Role : Master ! Loader Version : 1.0.2.2 ! Linux Kernel Version : 2.6.19 ! Operation Code Version : 1.2.77.212 ! ! ! Software Watchdog Information ! Status : Enabled ! AutoReload : Enabled ! Information of Eth 1/25 ! Connector Type : LC ! Fiber Type : Single Mode (SM) ! Eth Compliance Codes : [0x00] ! Baud Rate : 1300 MBd ! Vendor OUI : 00-25-CD ! Vendor Name : Gigalight ! Vendor PN : GPB-5324L-L2CD ! Vendor Rev : 11.0 ! Vendor SN : H23A03280068 ! Date Code : 23-05-23 ! DDM Information ! Temperature : ! Vcc : ! Bias Current : ! TX Power : ! RX Power : ! DDM Thresholds ! Low Alarm Low Warning High Warning High Alarm ! ----------- ------------ ------------ ------------ ------------ ! Temperature(Celsius) -10.00 -5.00 80.00 85.00 ! Voltage(Volts) 2.90 3.00 3.60 3.70 ! Current(mA) 10.00 12.00 60.00 65.00 ! TxPower(dBm) -13.00 -12.00 0.00 1.00 ! RxPower(dBm) -26.99 -26.02 0.00 1.00 ! ! Information of Eth 1/26 ! Connector Type : SC ! Fiber Type : Single Mode (SM) ! Eth Compliance Codes : 1000BASE-LX ! Baud Rate : 1300 MBd ! Vendor OUI : 00-90-65 ! Vendor Name : RCI ! Vendor PN : SFP-WDM-SM0220AD ! Vendor Rev : A ! Vendor SN : C2312181890 ! Date Code : 23-12-19 ! DDM Information ! Temperature : ! Vcc : ! Bias Current : ! TX Power : ! RX Power : ! DDM Thresholds ! Low Alarm Low Warning High Warning High Alarm ! ----------- ------------ ------------ ------------ ------------ ! Temperature(Celsius) -10.00 -5.00 75.00 80.00 ! Voltage(Volts) 3.00 3.10 3.50 3.60 ! Current(mA) 5.00 10.00 60.00 65.00 ! TxPower(dBm) -12.01 -11.00 -1.00 0.10 ! RxPower(dBm) -26.02 -25.09 -2.00 -1.00 ! ! Information of Eth 1/27 ! Connector Type : LC ! Fiber Type : Single Mode (SM) ! Eth Compliance Codes : [0x00] ! Baud Rate : 1300 MBd ! Vendor OUI : 00-90-65 ! Vendor Name : OEM ! Vendor PN : SFP-WDM1.25G-31D ! Vendor Rev : A0 ! Vendor SN : SH9V634035 ! Date Code : 19-02-02 ! DDM Information ! Temperature : ! Vcc : ! Bias Current : ! TX Power : ! RX Power : ! DDM Thresholds ! Low Alarm Low Warning High Warning High Alarm ! ----------- ------------ ------------ ------------ ------------ ! Temperature(Celsius) -45.00 -42.00 95.00 110.00 ! Voltage(Volts) 3.00 3.05 3.50 3.60 ! Current(mA) 2.00 3.00 70.00 80.00 ! TxPower(dBm) -16.00 -15.00 -8.00 -7.00 ! RxPower(dBm) -23.01 -22.01 -3.00 -2.00 ! ! Information of Eth 1/28 ! Connector Type : LC ! Fiber Type : Single Mode (SM) ! Eth Compliance Codes : BASE-BX10 ! Baud Rate : 1300 MBd ! Vendor OUI : 00-00-00 ! Vendor Name : OEM ! Vendor PN : SFBI-35G1-20(CS) ! Vendor Rev : A ! Vendor SN : N94242775 ! Date Code : 19-04-25 ! DDM Information ! Temperature : ! Vcc : ! Bias Current : ! TX Power : ! RX Power : ! DDM Thresholds ! Low Alarm Low Warning High Warning High Alarm ! ----------- ------------ ------------ ------------ ------------ ! Temperature(Celsius) -10.00 -5.00 75.00 85.00 ! Voltage(Volts) 3.00 3.10 3.50 3.60 ! Current(mA) 2.00 4.00 90.00 100.00 ! TxPower(dBm) -11.00 -10.00 -2.00 -1.00 ! RxPower(dBm) -27.21 -26.02 0.00 1.00 !