!01_e0-01-a6-e9-e0-a4_03 ! ! ! !--- !--- ! clock timezone EET hours 2 minute 0 ! ntp client ntp server 100.127.255.253 ntp server 100.127.255.254 ! prompt st-sw11-kpp hostname st-sw11-kpp snmp-server location "KPP, Gorodok" snmp-server contact admin@2funoff.com ! ! ! ! ! ! ! ! ! ! snmp-server community snmpkpp ro ! ! ! username admin access-level 15 username admin password 7 166b458e6e6b84e2608cc332e682de84 enable password 7 1b3231655cebb7a1f783eddf27d254ca ! ! logging facility 20 logging host 100.127.255.253 port 514 logging host 100.127.255.254 port 514 logging trap ! ! ! ! vlan database VLAN 1 name DefaultVlan media ethernet VLAN 36 name 36-telephony media ethernet VLAN 40 name 40-mgnt media ethernet VLAN 55 name 55-lan media ethernet ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! interface ethernet 1/1 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/2 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/3 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/4 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/5 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/6 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/7 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/8 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/9 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/10 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/11 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/12 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/13 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/14 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/15 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/16 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 36 untagged switchport mode access switchport native vlan 36 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/17 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/18 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/19 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/20 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/21 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/22 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/23 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/24 spanning-tree loopback-detection description _FREE_ no lldp notification no lldp admin-status switchport allowed vlan add 55 untagged switchport mode access switchport native vlan 55 switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ! interface ethernet 1/25 spanning-tree loopback-detection description sw0-kpp ip arp inspection trust ip arp inspection limit none switchport mode trunk switchport native vlan 40 switchport acceptable-frame-types tagged switchport allowed vlan add 36,40,55 tagged switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter ip dhcp snooping trust no loopback-detection ! interface ethernet 1/26 spanning-tree loopback-detection description _FREE_ switchport mode trunk switchport native vlan 40 switchport acceptable-frame-types tagged switchport allowed vlan add 40,55 tagged switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter no loopback-detection ! interface ethernet 1/27 spanning-tree loopback-detection description _FREE_ switchport mode trunk switchport native vlan 40 switchport acceptable-frame-types tagged switchport allowed vlan add 40,55 tagged switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter no loopback-detection ! interface ethernet 1/28 spanning-tree loopback-detection description sw12-kpp switchport mode trunk switchport native vlan 40 switchport acceptable-frame-types tagged switchport allowed vlan add 40,55 tagged switchport allowed vlan remove 1 no spanning-tree port-bpdu-flooding spanning-tree spanning-disabled spanning-tree bpdu-filter no loopback-detection ! ! ! ! ! interface vlan 40 ip address 192.168.12.15 255.255.255.0 ! ! ! ! ! ! management http-client 10.20.1.1 10.20.1.1 management http-client 192.168.12.1 192.168.12.254 management snmp-client 10.20.1.1 10.20.1.254 management snmp-client 100.127.255.254 100.127.255.254 management snmp-client 192.168.12.1 192.168.12.254 management telnet-client 10.20.1.1 10.20.1.250 management telnet-client 100.127.255.254 100.127.255.254 management telnet-client 192.168.12.1 192.168.12.254 ! ! ! ! ! ! ! ! ! ! ! ip route 0.0.0.0 0.0.0.0 192.168.12.1 ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ip dhcp snooping ip dhcp snooping vlan 55 ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! interface vlan 40 ! ! ! ! ! ! ! ! ! ! ! line console ! ! line vty ! ! ! end ! ! System Description : ECS4100-28T ! System OID String : 1.3.6.1.4.1.259.10.1.46.104 ! System Information ! System Name : st-sw11-kpp ! System Location : KPP, Gorodok ! System Contact : admin@2funoff.com ! MAC Address (Unit 1) : E0-01-A6-E9-E0-A4 ! Web Server : Enabled ! Web Server Port : 80 ! Web Secure Server : Enabled ! Web Secure Server Port : 443 ! Telnet Server : Enabled ! Telnet Server Port : 23 ! Jumbo Frame : Disabled ! Unit 1 ! ! Main Power Status : Up ! Unit 1 ! Serial Number : EC2239005043 ! Hardware Version : R02A ! Number of Ports : 28 ! Main Power Status : Up ! Role : Master ! Loader Version : 1.0.2.2 ! Linux Kernel Version : 2.6.19 ! Operation Code Version : 1.2.77.212 ! ! ! Software Watchdog Information ! Status : Enabled ! AutoReload : Enabled ! Information of Eth 1/25 ! Connector Type : SC ! Fiber Type : Single Mode (SM) ! Eth Compliance Codes : BASE-BX10 ! Baud Rate : 1300 MBd ! Vendor OUI : 00-00-00 ! Vendor Name : RCI ! Vendor PN : SFP-WDM-SM-0203A ! Vendor Rev : 1.0 ! Vendor SN : C2209190018 ! Date Code : 22-09-19 ! DDM Information ! Temperature : ! Vcc : ! Bias Current : ! TX Power : ! RX Power : ! DDM Thresholds ! Low Alarm Low Warning High Warning High Alarm ! ----------- ------------ ------------ ------------ ------------ ! Temperature(Celsius) -10.00 -5.00 75.00 80.00 ! Voltage(Volts) 3.00 3.10 3.50 3.60 ! Current(mA) 5.00 7.00 60.00 70.00 ! TxPower(dBm) -15.00 -14.50 -3.00 -2.50 ! RxPower(dBm) -28.86 -27.96 -4.00 -2.00 ! ! Information of Eth 1/26 ! No SFP inserted ! ! Information of Eth 1/27 ! No SFP inserted ! ! Information of Eth 1/28 ! Connector Type : SC ! Fiber Type : Single Mode (SM) ! Eth Compliance Codes : [0x00] ! Baud Rate : 1300 MBd ! Vendor OUI : 00-00-00 ! Vendor Name : RCI ! Vendor PN : SFP-WDM-SM-0203A ! Vendor Rev : A0 ! Vendor SN : 2023021600249 ! Date Code : 23-02-17 ! DDM Information ! Temperature : ! Vcc : ! Bias Current : ! TX Power : ! RX Power : ! DDM Thresholds ! Low Alarm Low Warning High Warning High Alarm ! ----------- ------------ ------------ ------------ ------------ ! Temperature(Celsius) -10.00 -5.00 75.00 85.00 ! Voltage(Volts) 3.00 3.10 3.50 3.60 ! Current(mA) 1.00 1.50 65.00 70.00 ! TxPower(dBm) -13.00 -12.00 -2.00 -1.00 ! RxPower(dBm) -30.00 -26.99 -3.00 -2.00 !